MASS FLOW CONTROLLER SS H2_1135073
Representative image only

MASS FLOW CONTROLLER SS H2

Accuracy±1% full-scale
CertifiedYes
Communicationslinear 0 to 5 VDC (1000 Ω minimum load), 4 to 20 mA (50 to 500 Ω loop resistance)
DescriptionCompact Gas Mass Flow Controller, 0-500 sccm, H2, Stainless Steel Body
Display Type3.5-digit LCD, detachable
Gas typeHydrogen
Height (Inch)5.625
Leak Integrity1 X 10-9 sccs He (max)
Length (Inch)1
Material O-RingViton
Max flow rate (LPM)0.5
Max Operating Temperature (DegreeC)50
Max Operating Temperature (DegreeF)122
Max Particulate Size (microns)5
Max pressure (psi)1000
Media TypeAcetylene;Air;Argon;Carbon Dioxide;Carbon Monoxide;Helium;Hydrogen;Nitrogen;Oxygen, Helium, Oxygen, Nitrogen, Water, Air, Air;Nitrogen, Argon, Hydrogen
Min flow rate (LPM)0
Min Operating Temperature (DegreeC)0
Min Operating Temperature (DegreeF)32
Output0 to 5 VDC (1000 Ω minimum); linear 4 to 20 mA (50 to 500 Ω loop resistance)
Output (Voltage)Yes
Power12 VDC
Pressure drop at maximum flow (PSID)1.06
Process connection1/4" Compression
Repeatability±0.25% full-scale
Response Time (msec)2000
Wetted MaterialsStainless Steel, Viton
Width (Inch)4.75
View Virtual Catalog - English - gy44-0371.pdf
Overview
  • Precisely control flow rates with built-in valve
  • Proven design uses metal body components for added durability
  • Accumulated flow can be logged using an optional totalizer
  • Includes NIST-traceable certificate

These controllers feature an advanced U-shaped sensor that ensures accurate and repeatable results. Gas flow measurements are unaffected by moderate temperature and pressure variations at the inlet. The meter also allows a four-point calibration across the flow range to improve meter linearity.

The flow rate set point can be established by either a local potentiometer or by a remote 4 to 20 mA or 0 to 5 VDC signal. Output data is sent via a 0 to 5 VDC or 4 to 20 mA signal; an analog-to-RS converter is also available for data collection and analysis on your PC.

All controllers include a detachable 3-1/2-digit LCD that can be tilted up to 90° for easy reading. The display is remote mountable to three feet using extension cable 32662-70. The totalizer option 32650-22 will display total accumulated flow.

The controller is protected from polarity reversal or short circuit by a built-in resettable fuse. Aluminum models have wetted materials of anodized aluminum, brass, and Viton; stainless steel (SS) models have wetted materials of SS and Viton.

Response Time:
Generally 2 seconds to within 2% of actual flow rate over 25 to 100% of full scale.

Accuracy:
These precalibrated flow controllers operate at inlet pressures between 5 and 60 psi and at gas temperatures between 59 and 77°F (15 to 25°C) while maintaining the stated percent full-scale accuracy and linearity. When operating beyond 5 to 60 psi, add ±0.01%/psi full-scale; if operating beyond 59 to 77°F (15 to 25°C), add ±0.15%/°C full-scale.

Whats Included:

NIST-traceable calibration report supplied by the manufacturer.