Cole-Parmer Single-Channel Digital Flame Photometer_1082027
Representative image only

Cole-Parmer Single-Channel Digital Flame Photometer

Air supply6 L/min at 11 psi; oil and moisture free
Aspiration rate2 to 6 mL/min
Depth (cm)34.5
Depth (InchShort)13.5
DescriptionSingle-Channel Digital Flame Photometer
Display3.5-digit LED; 12.5 mm (1/2") H
Fuel supplyHigh-grade propane/butane, or propane/butane mixture regulated at approximately 30 psi; natural gas at 3 to 10" W.G.
Height (cm)51
Height (InchShort)20
LinearityBetter than 2% mid range with Na=3 ppm, k=3 ppm, or Li=5 ppm
Power (Hz)50/60
Power (VAC)120 / 240
Range0 to 199.9 ppm
Reading stabilizationApproximately 8 seconds
Reproducibility< 1% CV from the same bulk sample for 20 determinations at Na and K=10 ppm
SensitivityTo display a min of 100 units, Na <0.5 ppm, K <0.5 ppm, Li < 5 ppm, Ca 5 ppm, Ba 200 ppm
SpecificityNa, K, Li interference is less than 0.5% of concentration of Na, K, Li, Ca, or Ba, equal to the concentration under analysis
Width (cm)39
Width (InchShort)15.375
Literature
Instruction Manual
View Virtual Catalog - English - gy44-0344.pdf
Overview
  • Unit comes with Na, K, and Ca filters; optional filter for Li is available Built-in secondary regulator and thermally insulated chimney for added safety

This digital flame photometer is designed with user ease and comfort in mind. The sample introduction port is located in the front. Filter replacement is made easy - there's no need to dismantle large sections of the unit. Special features ensure workplace safety, including an automatic gas shutoff if the flame becomes accidently extinguished, as well as a thermally insulated chimney. Unit offers a wide measuring range of 0 to 1999.
Optional linearizer module 02656-10 (use to increase accuracy with biological samples) and optional automatic dilutor 02657-00 are available. Optional barium filter 02655-40, optional lithium filter 02655-55, and three-position filter holder 02655-52 (required for barium and lithium filters) are sold separately. Use the 02657-25 Autosampler to provide a fully automatic analysis solution for long sample runs (requires the 02656-10 Digital Interface and 02656-15 Software for use with the Single-Channel Flame Photometer). Optional Automatic Dilutor will accurately dilute your samples and standards.

Whats Included:

a built-in secondary regulator, one each of Na+/K+/Ca+ filters, one each of 1000-ppm Na+/K+/Ca+ standards in 500-mL bottles, two meters each of gas and air tubing, plus all necessary connec