Digi-Sense, Pro 4-Input Data Logging Thermocouple Thermometer, Type K, NIST-Traceable Calibration_1119478
Representative image only

Digi-Sense, Pro 4-Input Data Logging Thermocouple Thermometer, Type K, NIST-Traceable Calibration

$841.50

The price is inclusive of GST
Accuracy±0.15% of reading +1.8°F; ±0.5% of reading +3.6°F below -148°F [±0.15% of reading +1.0°C; ±0.5% of reading +2.0°C below -100°C]
Battery9V battery (1)
Data LoggingYes
DescriptionPro 4-Input Data Logging Thermocouple Thermometer, Type K, NIST Traceable Cal
Display TypeBacklit LCD
Height (InchShort)8
IR Temperature Accuracy±2% of reading +3.6°F; ±9.0°F below 14°F [±2% of reading +2.0°C; ±5°C below -10°C]
Low battery indicatorYes
Max IR Temperature (DegreeC)-31
Max IR Temperature (DegreeF)-35
Max Temperature (DegreeC)1372
Max Temperature (DegreeF)2501
Memory Capacity10000 data points
Meter Measurement TypeThermocouple
Min IR Temperature (DegreeC)550
Min IR Temperature (DegreeF)1022
Min Temperature (DegreeC)-200
Min Temperature (DegreeF)-328
No. of Probe(s) Included4
Number Of Probe Channels4
OutputUSB
Resolution0.1°; 1° above 999.9°
Types Of Probes AcceptedType K
Literature
Instruction Manual
Software
Data Sheet
View Virtual Catalog - English - gy44-0937.pdf
Overview
  • Rugged, heavy-duty construction protects against knocks and jars
  • Reliable measurements, guaranteed! Precalibrated to NIST-traceable standards
  • Relative time stamp provides a time reference for major events
  • Electronic off set function allows compensation of probe errors
  • Infrared input port allows safe, noncontact measurements with optional IR wand

These professional type K thermometers provideaccurate and... reliable temperature measurement in an ergonomic design. Double-molded heavy-duty housing provides superior protection, making them ideal for tough applications. Plus the NIST-traceable precalibration means you get reliable measurements right out of the box, saving you time and money!

All models feature Min/Max/Avg, Hold, °F/°C or Kelvin (K) selectable units, relative time stamp on Min/Max/Avg, electronic offset function, temperature differential, backlit display, and auto power-off. Accept a wide variety of type K thermocouple probes with miniconnector.

These meters also feature an infrared input that accepts an optional IR wand for noncontact measurements of objects that are difficult or dangerous to reach; order wand 20250-24 separately below. The IR temperature reading can be used as a unique input when calculating temperature differential. The IR wand has a distance-to sight ratio of 8:1 and temperature range of –31 to 1022°F (–35 to 550°C). Model 20250-20 includes all the same features as 20250-17 plus four independent channels with data logging up to 10,000 readings. Easily download the data to a PC via USB interface, and analyze the data graphically with included software.

Whats Included:

Type K bead wire temperature probe (one for each input), hard carrying case, one 9 V battery, and NIST-traceable calibration report with data supplied by InnoCal. Data logging models 20250-19 and -20 also include USB cable and software.

Over 40,000 Customers Trust John Morris