Steriliser SF110plus, forced air circulation,TwinDISPLAY, 108 l, 20 °C - 250 °C with 2 grids_1223951
Representative image only

Steriliser SF110plus, forced air circulation,TwinDISPLAY, 108 l, 20 °C - 250 °C with 2 grids

$8,332.50

The price is inclusive of GST
Capacity (Liters)108
External dimensions W x H x D745 x 864 x 584 mm
Internal dimensions W x H x D560 x 480 x 400 mm
Number of Shelf Positions5
Number of Shelves2
Power (Hz)50/60
Power (VAC)230
Temperature Accuracy±0.1°C up to 99°C, ±0.5⁰C above 100⁰C
TimerYes
Timer RangeAdjustable between 1 minute and 99 days, 23 hours
Working Temp Range (°C)+5 (above ambient) to 300
Memmert-Steriliser-SF110plus
Overview
  • intuitive and easy-to-use operating menu
  • SetpointWAIT function ensures that the programme is only continued when the setpoint temperature is reached
  • almost exclusive use of high-quality, corrosion-resistant and easily cleanable stainless steel for the working chamber and housing
  • heating concept specifically adapted for a precise and homogenous temperature control
  • a wide range of options for reading and data logging using interfaces, integrated data logger and Software AtmoCONTROL
  • 3 years guarantee worldwide

The Memmert steriliser S complies with all relevant standards and regulations for medical devices and guarantees reliable programme sequences, irrespective of the load and chamber volume. Especially due to the SetpointWAIT function the validation of a Memmert hot air steriliser is possible anytime. Combined with the user-ID function the optional process-controlled, electromagnetic door lock of appliances with model variant TwinDISPLAY is the icing on the cake in terms of safety in the laboratory.

Disinfection of appliances and instruments is not sufficient in medicine and research. Only sterilisation provides sufficient protection. In the Memmert hot-air steriliser, the SetpointWAIT function ensures that the programme is only continued when the setpoint temperature has been reached.

Precisely maintaining the sterilisation time and thus completely killing off even highly resistant microorganisms is therefore guaranteed at all times, irrespective of the sterilisation load and chamber volume. This feature can also be used with additional, freely positionable Pt100 temperature sensors. In this case, sterilisation only begins when the setpoint temperature has been reached at all measurement points – that is, in the load. For the special application of depyrogenisation, the hot-air steriliser S is absolutely ideal.